| Location |
System Voltage (kv) |
Conductor (mm²) |
Cable Length (km) |
Year Ordered |
Features |
Nagoya S/S Japan |
275 |
800 |
0.4 |
1979 |
Installed in substation and terminated by outdoor ends. |
Ikegami S/S Japan |
275 |
800 |
0.5 |
1984 |
Installed in substation and terminated by oil-immersed ends and SF6 ends. |
Shajiao China |
220 |
1200 |
8.6 1.2 |
1984 1985 |
Installed in substation and terminated by outdoor ends and SF6 ends. |
Minami Ikegami Japan |
275 |
1400 |
5.4 5.4 |
1986 1989 |
Installed in underground transmission line and jointed by Extrusion molded joints (24/EMJ). |
Minami Route Japan |
275 |
2500 |
50.3 |
1989 |
Installed in underground transmission line and jointed by Extrusion molded joints (102/EMJ). |
Chushin S/S Japan |
275 |
600 |
1.9 |
1991 |
Installed in substation and terminated by oil-immersed ends, outdoor ends and SF6 ends. |
Beijing China |
220 |
630 |
9.0 |
1991 |
Installed in underground transmission line, terminated by prefabricated outdoor ends, and jointed by prefabricated joints (12/PJ). |
Nankatsu-Setagaya Japan |
275 |
1400 |
68.2 |
1991 |
Installed in underground transmission line, terminated by SF6 ends and jointed by Extrusion Molded Joints(99/EMJ). |
Yokohama-Kouhoku Japan |
275 |
2500 |
32 11.3 |
1992 1994 |
Installed in underground transmission line, and jointed by Extrusion Molded Joints(90/EMJ) |
Minami Souma S/S Japan |
275 |
2000 |
3.9 |
1993 |
Installed in S/S and terminated by outdoor ends and SF6 ends. |
Ozone Japan |
275 |
1500 |
20 |
1993 |
Installed in underground transmission line, terminated by outdoor ends and jointed by Prefabricated Joints (48/PJ). |
Tokau-Matsugae Japan |
275 |
2500 |
19.8 |
1995 |
Installed in underground transmission line, and jointed by Extrusion Molded Joints(12/EMJ). |
Ama-Matsugae Japan |
275 |
2500 |
38.9 |
1996 |
Installed in underground transmission line, terminated by Sf6 ends and jointed by Extrusion Molded Joints(24/EMJ). |
Shinkeiyo-Toyosu Japan |
500 |
2500 |
59.5 |
1996 |
Installed in underground transmission line, terminated by SF6 ends and jointed by Extrusion Molded Joints (69/EMJ). |
Nishifukuoka Japan |
220 |
1500 |
11.3 |
1996 |
Installed in underground transmission line, terminated by SF6 ends and jointed by Prefabricated Joints(21/PJ). |
Beijing China |
220 |
1000 |
10.4 |
1997 |
Installed in underground transmission line, terminated by Prefabricted outdoor ends and jointed by Prefabricated Joints (15/EMJ) |
Toyosu-Uchisaiwaicho Japan |
275 |
1400 |
58.7 |
1997 |
Installed in underground transmission line, terminated by SF6 ends and jointed by Extrusion Molded Joints (63/EMJ). |
Okutataragi P/S Japan |
500 |
800 |
4.4 |
1997 |
Installed in water power station and terminated by Oil-immersed ends and SF6 ends. |
Koyna Hydro P/S India |
420 |
800 |
6.5 |
1997 |
Installed in water power station and terminated by outdoor ends and SF6 ends. |
Sannomiya Japan |
275 |
1500 |
30.0 0.54 |
1997 1998 |
Installed in underground transmission line, terminated by outdoor ends and jointed by Prefabricated Joints (48/PJ). |
Second Shuikou P/S Japan |
220 |
2000 |
0.7 |
1997 |
Installed in substation and terminated by Prefabricated outdoor ends. |
Tin Wan S/S Hong Kong |
275 |
400 |
0.25 |
1997 |
Installed in substation and terminated by Prefabricated SF6 ends. |
Zuoanmen Extension P/J China |
220 |
1500 |
0.26 |
1998 |
Installed in substation and terminated by Prefabricated outdoor and SF6 ends. |
Tachibanawan P/S Japan |
500 |
1000 |
4.80 |
1998 |
Installed in thermal power station and terminated by SF6 ends. |
Nishiosaka S/S Japan |
275 |
1000 |
0.26 |
1999 |
Installed in substation and terminated by Prefabricated SF6 ends. |
Kawasaki Karyoku-Ota Japan |
275 |
2500 |
20.24 |
1999 |
Installed in underground transmission line and jointed by Extrusion Molded Joints (9/EMJ) |
Jiangsu/Nanjing China |
220 |
800 |
45.0 |
1999 |
Installed in underground transmission line, terminated by prefabricated outdoor ends and SF6 ends, jointed by Pre-molded Joints (66/SPJ). |